Encoded PAUT & TOFD Volumetric Verification on Live Process Piping Tie-Ins
Full encoded PAUT + TOFD volumetric weld examination and MT/VT surface verification across 142 tie-in girth welds replacing radiography inside congested live process blocks.
Operational Context
Inspection / Technical Challenge
Executing volumetric code inspection on adjacent live-plant piping tie-ins without triggering plant-wide ionizing radiation exclusion perimeters that would delay simultaneous mechanical trades.
Scope & Execution Approach
Engineered weld-thickness-specific PAUT + TOFD scan plans calibrated on matching reference blocks, capturing 100% digital A/B/C/D-scan data indexed cleanly around every weld circumference alongside complementary MT root/cap checks.
Documented Outcomes
- Zero radiation exclusion disruptions to concurrent scaffolding, insulation, and mechanical crews.
- Permanent digital B/C/D-scan archive delivered per weld joint for full engineering audit traceability.
- Early root-defect characterization enabled targeted localized weld repairs before hydrotest.
Confirming weld-crown dressing quality and encoder clearance during fit-up eliminates scan delays when PAUT crews arrive.